6.9.3 Swimming Pools
Configuration and Design Requirements
| Pool Name |
|
| Applicability | All pools |
|---|---|
| Definition | A unique identifier that keys the pool to the construction documents |
| Units | Text, unique |
| Input Restrictions | None |
| Baseline Rules |
The name for the baseline building pool should be similar to the proposed design. |
| Volume |
|
| Applicability | All pools |
|---|---|
| Definition | The volume of the pool |
| Units | Cubic feet (ft³) |
| Input Restrictions | None |
| Baseline Rules |
Same as the proposed design |
| Surface Area |
|
| Applicability | All pools |
|---|---|
| Definition | The surface area of the pool affects heat loss and evaporation. |
| Units | Square feet (ft²) |
| Input Restrictions | None |
| Baseline Rules |
Same as the proposed design |
| Cover |
|
| Applicability | All pools |
|---|---|
| Definition | An indication |
| Units | Boolean (Yes/No) |
| Input Restrictions | None |
| Baseline Rules |
The baseline building shall have a pool cover per Section 7.4.5.2 of ASHRAE Standard 90.1-2007. |
| Cover Schedule |
|
| Applicability | All pools |
|---|---|
| Definition | A schedule indicating when the pool cover is in place |
| Units | Data structure: schedule, on/off or fractional |
| Input Restrictions | None |
| Baseline Rules |
Same as the proposed design |
| Filtration Rate |
|
| Applicability | All pools |
|---|---|
| Definition | The rate at which the pool water is passed through the filtering system when the filtration system is operating |
| Units | Hours per pool change |
| Input Restrictions | None |
| Baseline Rules |
Same as the proposed design |
| Filtration Schedule |
|
| Applicability | All pools |
|---|---|
| Definition | A schedule indicating when the pool filtration system is in operation |
| Units | Data structure: schedule, on/off or fractional |
| Input Restrictions | None |
| Baseline Rules |
Same as the proposed design |
| Temperature |
|
| Applicability | All pools |
|---|---|
| Definition | The temperature at which the pool is maintained |
| Units | Degrees Fahrenheit (°F) |
| Input Restrictions | None |
| Baseline Rules |
Same as the proposed design |
| Temperature Schedule |
|
| Applicability | All pools |
|---|---|
| Definition | A schedule indicating variation in the pool temperature, either seasonally or monthly |
| Units | Data structure: schedule, temperature |
| Input Restrictions | None |
| Baseline Rules |
Same as the proposed design |
Pumping and Filtration
| Pumping Power |
|
| Applicability | All pools |
|---|---|
| Definition | The power used by the pumping system. This is a function of the pumping head (which depends on pipe lengths, sizes, and filtration type), the pump efficiency, the motor efficiency, and the flow rate. Some software may allow these to be entered as separate building descriptors. This value should be consistent with the filtration rate noted above. |
| Units | Watts (W) |
| Input Restrictions | None |
| Baseline Rules |
Same as the proposed design unless the proposed design uses special low head filters and premium efficiency motors |
Heating Equipment
| Heater Type |
|
| Applicability | All pools |
|---|---|
| Definition | The type of equipment that is used to maintain the pool temperature |
| Units | List: solar, heat pump, gas, oil, or electric resistance |
| Input Restrictions | None |
| Baseline Rules |
If there is gas or oil on the site, the baseline building shall be modeled with a natural gas or oil pool heater meeting the requirements of Table 7.8 for ASHRAE Standard 90.1-2007. If there is no gas or oil on the site, the baseline building shall be modeled with a heat pump pool heater meeting the requirements of Table 7.8 for ASHRAE Standard 90.1-2007. |
| Heater Efficiency |
|
| Applicability | All pools with heaters |
|---|---|
| Definition | The thermal efficiency of the pool heater |
| Units | Unitless, thermal efficiency |
| Input Restrictions | None |
| Baseline Rules |
See the baseline building rules for heater type |
| Solar System Features |
|
| Applicability | All pools with solar pool heaters |
|---|---|
| Definition | The collector area, size, efficiency, and pumping characteristics of the solar pool system |
| Units | Data structure |
| Input Restrictions | None |
| Baseline Rules |
Not applicable. The baseline building has a pool cover, not solar |
- PDF Version of Visible Section/s
- Generate Complete PDF
- Printer-friendly Version
- Login or register to post comments
Select a Purpose
Download PDF
Book Navigation
- Commercial Buildings Energy Modeling Guidelines & Procedures (MGP)
- Acknowledgments
- 1 Overview
- 2 General Modeling Procedures
- 3 Software Requirements
- 4 Content and Format of Standard Reports
- 5 Energy Costs and Currency Specification
- 6 Building Decriptors Reference
- 6.1 Overview
- 6.2 Project Data
- 6.3 Thermal Blocks
- 6.4 Space Uses
- 6.5 Building Envelope Data
- 6.6 HVAC Zone Level Systems
- 6.7 HVAC Secondary Systems
- 6.8 HVAC Primary Systems
- 6.9 Miscellaneous Energy Uses
- 6.10 On-Site Power Generation
- 6.11 Common Data Structures
- 6.11.1 Schedule
- 6.11.2 Holidays
- 6.11.3 Surface Geometry
- 6.11.4 Opening Geometry
- 6.11.5 Opening Shade
- 6.11.6 Construction Assembly
- 6.11.7 Fenestration Construction
- 6.11.8 Material
- 6.11.9 Slab Construction
- 6.11.10 Exterior Surface Properties
- 6.11.11 Building Shade
- 6.11.12 Utility Rate
- 6.11.13 Occupant Heat Rate
- 6.11.14 Furniture and Contents
- 6.11.15 Reference Position in a Space
- 6.11.16 Two Dimensional Curve
- 6.11.17 Three Dimensional Curve
- 6.11.18 Temperature Reset Schedule
- 6.11.19 Photovoltaic (PV) Panel
- 6.11.20 Contact
- 7 Advanced Modeling Tips
- 7.1 Challenging Building Types
- 7.2 Design Features
- 7.2.1 Automatically Controlled Window Shades
- 7.2.2 Active Chilled Beams
- 7.2.3 Dedicated Outside Air Systems (DOAS)
- 7.2.4 Displacement ventilation
- 7.2.5 Gas Engine Driven Heat Pumps
- 7.2.6 Ground Source Heat Pumps
- 7.2.7 Ice Storage Air Conditioners
- 7.2.8 Radiant Heating and/or Cooling
- 7.2.9 Switchable glazing
- 7.2.10 UFAD
- 7.2.11 Variable Refrigerant Flow
- Download Appendices